Search

VentiMyst®

Ventilator breathing systems with advanced active humidification: the humidity your patient needs, with condensation kept under control.

Fewer circuit breaks

Less need to open or break the circuit to drain excess condensation, reducing the risk of ventilator-associated pneumonia.1

Stable flow resistance

Lower likelihood of increased gas flow resistance caused by fluid building up in the expiratory limb or filter.2

Reduced contamination risk

Lower risk of contamination reaching the ventilator or the patient.

VentiMyst® Advanced Active Humidification

VentiMyst® delivers absolute humidity while keeping excess condensation under control.

Active humidification with respiratory humidifiers and heated wire breathing circuits brings many clinical benefits, but it can also lead to problems such as condensation building up in the circuit.

VentiMyst® addresses this by preventing condensation from accumulating in the expiratory limb.

VentiMyst® Moisture Management Technology

Less condensation build-up compared with standard corrugated heated tubes.

Standard corrugated heated wire limb

Condensation collects in the corrugations of the limb.

VentiMyst®

No condensation build-up.

Advanced active humidification with less condensation3

Lower patient risk

Reduces the risk of condensate accidentally draining into the patient’s airway.4

Clinical confidence

Less need to open or break the circuit, avoiding loss of PEEP and the associated lung derecruitment.5

Effective moisture management

VentiMyst® technology reduces condensation build-up.

Dual-valve auto-fill chamber

Two independent floats, together with primary and secondary valves, regulate water flow into the chamber for effective protection against overfilling.

Efficient temperature transfer

Helps prevent gas temperature loss and cold spots on the tube surface, minimizing condensation.

Low-resistance tubing

Accurate delivery of gas volumes and ventilation pressures to the patient.

VentiMyst® Adult

PART NUMBER DESCRIPTION ADDITIONAL COMPONENTS QUANTITY
038-31-252 VentiMyst® Adult Dual Heated Wire with Pressure Line – Kit 1 22 mm, 1.6 m adult dual heated wire breathing system with VentiMyst® corrugated expiratory limb, Y-piece with MDI port and pressure port, 0.5 m limb, pressure line, 22M/22M, 15F connector, 22F/22M elbow and auto-fill chamber 10
038-31-253 VentiMyst® Adult Dual Heated Wire without Pressure Line – Kit 2 As Kit 1, without pressure line 10

VentiMyst® Neonatal

PART NUMBER DESCRIPTION ADDITIONAL COMPONENTS QUANTITY
038-33-252 VentiMyst® Neonatal Dual Heated Wire with Auto-Fill Chamber – Kit 1 15 mm, 1.6 m neonatal dual heated wire breathing system with VentiMyst® corrugated expiratory limb, Y-piece with suction port, 0.3 m 15 mm incubator extension, T-pieces with 8M/8F ports, 22M/22M, 15F connector, 8M/15M connector, adaptor tube, 22F/22M elbow, 9-11F/22M, 15F connectors, 10M, 8F/15M, 11F connectors, 15F/22F heated wire adaptor, detachable pressure line, 0.15 m 9-11F/9-11F limb, 0.6 m 22F/22F limb, 0.6 m 15M, 11F/22F limb and auto-fill chamber 10
038-33-253 VentiMyst® Neonatal Dual Heated Wire without Chamber – Kit 2 As Kit 1, without humidification chamber 10

VentiMyst® Neonatal for SLE ventilators

PART NUMBER DESCRIPTION ADDITIONAL COMPONENTS QUANTITY
038-33-252/S VentiMyst® Neonatal Dual Heated Wire for SLE Ventilator with Auto-Fill Chamber – Kit 1 15 mm, 1.6 m neonatal dual heated wire breathing system with VentiMyst® corrugated expiratory limb, Y-piece with suction port and fixed pressure line, 0.3 m 10 mm incubator extension, 22M/22M, 15F connector, T-piece with 8M/8F port, 22F/22M elbow, 15M-22M/15F connectors, red and amber flow restrictors, 0.15 m 9-11F/9-11F limb, 0.6 m 9-11F/22F limb, 0.6 m 15M, 11F/22F limb and auto-fill chamber 10
038-33-253/S VentiMyst® Neonatal Dual Heated Wire for SLE without Chamber – Kit 2 As Kit 1, without humidification chamber 10